Click on any linkable error code below for more information. In some instancesit may be more prudent to contact a local repairman or send Spa Care Centeryour control box for evaluation/repair. Please note that the Balboa Error Codes cover all circuit board manufactured by Balboa including Cal Spa, Marquis Spa, Master Spa and many others. Gecko Error Codes also cover any control box manufactured by Gecko.
For information regarding repairsclick here If you needfurther help with troubleshootingclick here
For information regarding repairsclick here If you needfurther help with troubleshootingclick here
Balboa Spa Side Error Codes For more information regarding Balboa tech supportclickhere pd Power supply, unit running on battery backup OH Sensors reading 112-118° F. OHH Overheat. Spa has shut down. One sensor has detected118º F at heater. OHS Overheat. Spa has shut down. One sensor has detected110º F. Flo Improper flow or pressure switch malfunction Cool Water temp 20° below set point ICE Potential freeze condition has been detected Sn1 Hi-limit sensor malfunction Sn3 Temp sensor malfunction SnA Spa is shut down. Sensor plugged into jack Ais not working. Snb Spa is shut down. Sensor plugged into jack Bis not working. SnS Sensors out of balance. If alternating with temp,may be temporary condition. If display shows only this message (blinking)spa is shut down. HFL Substantial difference between temperature sensorsdetected. Could indicate a flow problem. LF Persistent low flow problems. (Displays on the5th occurrence of 'HFL' message with 24 hours). Heater is shut down,but other spa functions run normally. dr Inadequate water detected in heater. dry Inadequate water detected in heater. (Displayson third occurrence of 'dr' message). Spa is shut down. Pr When spa is first actuated, it will go into PrimingMode. ILOC Interlock failure - possible pump or ozone spike. (---) Unknown water temperature. (Displays when firstpowered up after refill). Std Spa operating in Standard Mode. Ecn Spa operating in Economy Mode. SL Indicates spa is in Sleep mode SF Safety Suction, Spa is shut down. SE Spa operating in Standard-in-Economy Mode. Gecko Spa Side Error Codes FLO Pressure switch failure, switch open FLC Pressure switch failure, switch closed Prr Temp sensor failure Prh Hi-limit sensor failure HL Sensor measuring 119 degrees FrE Possible freeze condition detected Hurricane Spa Side Error Codes PS Flow or pressure switch failure SH Shorted sensor OP Open Sensor Degrees LO Temp below 60 degrees - freeze HL Temp above 118 degrees OH Spa temp exceeds acceptable limits FLO Flow problem ICE Freeze condition detected SN1 Hi-limit sensor failure SN2 Temp sensor failure Spa Quip Spa Side Error Codes err 1 (H20) Prime Failed err 3 Stuck Button err 4 No Water Sensor err 5 Overtemperature err 6 Thermal Cut Out Tripped err 7 Stuck Relay err 8 No Temperature Data 01 Stuck Button 02 No Controller Data 03 Temperature Sensor 04 Water Sensor 05 Spa Over Temperature 06 Heater Thermal Cut Out 07 Stuck Heater Relay 09 Water Prime Failed Hydro-Quip Spa Side Error Codes For more information regarding Hydro-Quip tech supportclick here C Celsius CL Current Time of Day ECdu Economy Mode Duration Econ Economy Mode Turn On F Fahrenheit Fldu Filter Cycle Duration Flon Filter Cycle Turn On FLC Pressure Switch Alarm FLO Pressure Switch Alarm FrEE Freeze Protection Alarm HL High Temperature Alarm Loc Panel / Keypad Locked PrH Temperature Sensors Alarm Prr Temperature Sensors Alarm Tu Temperature Set Celsius Tu Temperature Set Fahrenheit Jacuzzi Whirlpool Spa Side Error Codes OH Overheat Protection (Heater is deactivated, pumpslow speed is activated). COOL Spa water is more than 20° F cooler than thetemperature set point. FLO Flow Switch (heater is deactivated. Pump mayalso be deactivated). Hold Panel sensors have been pressed too many timesin a short period of time. HOT Circuit Board temperature has exceeded acceptablelimit. ICE Freeze protection. No action is necessary. ICE2 Freeze protection. No action is necessary. PnL Communication between the panel and circuit boardis faulty. ---- Watchdog' (spa is deactivated) A problem hasbeen detected. Sn1 Open sensor (heater is deactivated) or Shortedsensor (spa is deactivated). Sn3 Open or shorted sensor ( heater disabled). FLO2 Closed or shorted flow switch on system startup Dream Maker Spa Side Error Codes OH Overheat Protection (Heater is deactivated, pumpslow speed is activated). FL Spa water is more than 20° F cooler than thetemperature set point. SN Flow Switch (heater is deactivated. Pump mayalso be deactivated). F2 Panel sensors have been pressed too many timesin a short period of time. F4 Circuit Board temperature has exceeded acceptablelimit. F6 Freeze protection. No action is necessary. FC Freeze protection. No action is necessary. Sundance Spa Side Error Codes For more information regarding Sundance tech supportclick here ILOC Interlock failure - possible pump or ozone spike FLO Pressure switch malfunction Hold Panel buttons pressed to many times to quickly HOT PCB temperature above acceptable limit - airblower on ICE Potential freeze condition Pnl Communication between PCB and panel interrupted Sn1 Hi-limit sensor failure Sn3 Temp sensor failure Vita Spa Side Error Codes HiLi Water temp over acceptable limit BJ2P Pump/Blower purge - normal condition PS / FLO Insuffcient water flow through heater. FP Freeze protect-temp under acceptable condition SS=0;SS=S;LS=O;LS=S Multiple causes; open sensors, bad connectionto panel, improper voltage, etc. Brett Spa Side Error Codes For more information Regarding Brett Aqualine techsupportclick here OH Temp exceeds 118 degrees Fr Freeze condition - temp below 40 degrees FL Pressure switch failure EO Shorted temp sensor E1 Open temp sensor E2 Shorted hi-limit sensor E3 Open hi-limit sensor E4 Shorted flow switch E7 Improper electrical connection Hercules Spa Side Error Codes OH Spa temp exceeds acceptable limits FLO Flow problem ICE Freeze condition detected SN1 Hi-limit sensor failure SN2 Temp sensor failure ACC (Applied Computer Controls) CoLd Temperature in the spa heater housing is below40° F. Status of the heater element is unknown. The low speed pump orcirc pump will operate continuously until the temperature rises above45° F. OH Over heat. The spa is at a temperature above108° . Do not use spa when temperature is flashing or the OH messageis displayed. HLoH Hi Limit Over Heat. Hi limit sensor is disconnectedor shorted or the spa temperature is above 112° F. SEoP Sensor open or disconnected. Heater disabledbut the spa is operational. SESH Sensor short, nonfunctional. Heater disabledbut the spa is operational. PSoC Pressure switch open with circulating pump. PSoL Pressure switch open with low pump. PSoH Pressure switch open with high pump. ToE Time out error. Rare system error. Spa unusable. Spa Builders Spa Side Error Codes For more information regarding Spa Builders tech supportclickhere Sn1 Nonfunctional high temperature sensor. Heateris deactivated. Sn2 Nonfunctional temperature sensor. Heater is deactivated. FL1 Water flow problem, inhibited or pressure switchmalfunction. Check for proper spa water level and ensure pump is primed.Check for clogged filter. FL2 Pressure switch problem. Switch closed whilepump is deactivated. COL Cool condition. If water temperature drops 20ºFbelow set temperature, low speed pump and heater activates to bringtemperature within 15º of set temperature. ICE Freeze condition. 55ºF detected. Low speed pumpand heater will activate until spa reaches 65ºF. OH High temperature condition, has reached 110ºF.Do not enter the spa. Low speed pump (and air blower if so equipped)will activate to assist in lowering temperature.
--- = 'Watchdog'.Water temperature has reached 118ºF. Entire system is disabled. Contactqualified service technician.CTI Spa Side Error Codes For more information regarding CTI tech supportclick here th1/39 On startup indicates temperature probe problem. th2/current temperature On startup indicates temperature probe problem. th3/39 On startup indicates water temperature less than39° F. OH Overheating, water over 112° F. System will restartwhen temp. drops. hot Overheating, water over 112° F. System will restartwhen temp. drops. HL High limit switch tripped. Blue Ridge Spa Side Error Codesclick here Gatsby Spa Spa Side Error Codesclick here Imperial Spa Spa Side Error Codesclick here Swift River Spa Side Error Codesclick here Winchester Spa Error Codesclick here
1 flash - 3 second gap | High Limit fault |
---|---|
2 flashes - 3 second gap | Pressure/Flow switch short circuit |
3 flashes - 3 second gap | Pressure/Flow switch open circuit |
4 flashes - 3 second gap | Open circuit Sensor(s) |
Flash - 1 second on, 1 second off | Same as OH |
Flash - briefly OFF once per second | Same as Sn1 or Sn3 |
Flash - briefly ON once per second | Same as FLC |
Blinking Power Indicator Light - Hydromate | High Limit tripped or, sensor fault |
1 flash per second - onga 4352, 53, 95, etc | Pressure switch open circuit - could also be motor,or motor thermal overload |
3 flashes per second - onga 4352, 53, 95, etc | Electronic fault - sensor (most common cause) orPCB |
Green flashes - Spaquip Pulsar/2095 series | Water sensor fault - lack of water |
Red/Green alternate flashes | Temperature sensor fault, open circuit, or high limittripped - push Reset Rod |
We have a Hotsprings/Watkins brand hottub/spa that came with the house we bought last September. At the time that we bought it, the hot tub appeared to work and heat up properly. However, now that we've unwinterized it and tried to use it, it no longer heats up and the water temperature stays at 70 F. The power to the hottub works ok and the jets, light and control panel all seem to work ok.
At first we found that the circulation pump wasn't working and we though that this is why the water wasn't heating up. We bought a new pump and now the bubbles come out of the bottom circulation vent at the bottom of the tub, but the water still doesn't heat up. Does this sound like a problem with the heating element? We're not really familiar with hot tubs and aren't sure how to troubleshoot this other than look at the obvious. People online talk about breakers in the inside control panel, but I couldn't find any and the only fuse in there is in tact. The only breaker I know of is the external breaker in a breaker box outside the hot tub. Any ideas are appreciated.
Kate Gregory1,20822 gold badges1414 silver badges2020 bronze badges
deltaraydeltaray21122 gold badges33 silver badges1515 bronze badges
3 Answers
Deltaray,
I have a Hotsprings Grandee 220V. I've experienced a few power related issues. Here are my thoughts:
- Makse sure the thermostat is set higher than 70 degrees. Should be a no brainer but you never know.
- Make sure the breaker for the heater is on. Mine has 2 breakers in the sub panel, one for the heater and one for the pumps and electronics.
- Try resetting everything. Turn off the breakers, let it site for a minute, turn the breakers back on.
- On mine the cover for the control box is easy to open with a screwdriver. Turn off the breakers and open the control box. Examine the wires that go to the heater. Make sure they are attached.
- Mine also has a fuse or two on in the control box. Look to see if they are blown.
- The heaters do not last forever. They are pretty simple to replace, especially if you already have experience replacing the circulation pump.
- If you are comfortable with electricity it is easy to see if the heater is getting power at the control box. Use a volt meter to check for voltage.
- If the circulation pump was not working, the heater could have overheated. Look for a reset button, or if you know the heater is getting power, replace the heater.
![Lay z spa error 02 Lay z spa error 02](/uploads/1/2/3/7/123701326/645571881.jpg)
When the heater is working you should feel hot water coming out of the drain vent. Your electric meter should also be spinning pretty fast. My Grandee takes a few hours to heat up, but you should feel the hot water almost immediately.
What year/model do you have? 110V or 220V?
Scott BrunsScott Bruns1,82311 gold badge1111 silver badges1212 bronze badges
Just throwing it out there, but many spa heaters, including mine, have an 'overheat breaker' for the heater coil, which trips if the heater element gets too hot. For instance, if the pump wasn't well-primed before you turned the heater on, you can have air in the heater manifold which very quickly overheats the coil. Turning the element to its max setting can also cause this breaker to trip every so often.
The breaker should have a pretty simple reset; on mine it's just a small red button.
KeithSKeithS12.8k77 gold badges3333 silver badges7070 bronze badges
Just one more idea: my hot tub heater automatically resets to 'warm' vs. 'hot' if the filter needs to be changed. I have a different make/model, but check your filters.
Also, they can take hella long time to heat in cool weather.
ssaltmanssaltman
protected by Community♦Jun 29 at 6:39
Thank you for your interest in this question. Because it has attracted low-quality or spam answers that had to be removed, posting an answer now requires 10 reputation on this site (the association bonus does not count).
Would you like to answer one of these unanswered questions instead?
Would you like to answer one of these unanswered questions instead?
Not the answer you're looking for? Browse other questions tagged water-heaterpoolhot-tub or ask your own question.
What You'll Need
Assorted Screwdrivers
Pipe Wrench
What You'll Need
Assorted Screwdrivers
Pipe Wrench
There are only a few things that can go wrong with a spa pump. The inlet or outline line could become clogged outlet. The pump may leak around the base, or it may not operate at all. Any malfunctions other than these should probably be attended to by a trained professional, but these problems may have simple solutions.
Lay Z Spa Error 33 1
Step 1: Diagnose the Problem
If your spa pump is leaking or or not flowing, examine it to find out what the problem may be. If the intake is not working, the problem might be a clog. Repair it by simply removing the obstruction. Similarly, there is no need to remove the pump if problems are caused by objects that have become jammed in the jets.
Step 2: Disconnect the Power
Do not perform any repairs on a hot tub pump until after the power has been disconnected. This may involve a circuit breaker or a separate box mounted near the pump. Never work on water-moving devices while the electricity is running.
Step 3: Remove the Pump
Remove the spa circulation pump. In most cases, this removal entails removing 4 to 8 bolts, but some models use other mounting methods. If you have trouble getting a bolt to turn, spray it with WD-40 or some other penetrating fluid, and allow the bolts to set for 5 to 10 minutes.
Step 4: Clean Connectors
Clean the connectors thoroughly. Check any washers or gaskets used in the connectors or the pump mounts. Replace worn or damaged gaskets. For a tighter seal, place a drop of oil on the washer or filter, and rub it into the entire surface.
Inspect the pump for any foreign objects that have gotten lodged inside it. Even a small piece of plastic could cause the pump to jam, rendering it ineffective.
Step 5: Remount the Pump
Carefully mount the pump back on the motor. If there is a gasket between the pieces, make sure it is properly in place before installing the bolts. To install bolts, snug each one in a clockwise direction, and then start over and tighten each bolt down, in the same pattern. This helps to give you an even, consistent seal.
Step 6: Restore Power and Test
Restore the power to the motor and turn it on. If all has gone well, the leaks will be fixed. If you still have leaks, repeat the process. If leaks are still present after a second attempt, you may need the services of a plumber.
Lay Z Spa Error 33 3
Step 7: Motor Problems
Lay Z Spa Error 33 Free
If the motor does not operate, your problem is not with the pump. Unless you have moderate experience in household electrical procedures, you should leave repairing a faulty electric motor to a trained technician. You can even remove the motor and take it to a repair center.